Advanced search

Show simple item record

dc.contributor.advisorCanahuire Cabello, Ruth Vanessa
dc.contributor.authorPalomino Barzola, Styven Felix
dc.date.accessioned2024-02-26T20:02:43Z
dc.date.available2024-02-26T20:02:43Z
dc.date.issued2024
dc.identifier.citationPalomino Barzola, S. F. (2024). Diseño e implementación de un prototipo de dispositivo háptico de 7 GDL orientado a cirugía con control fraccionario de torque y compensación de gravedad para el control de trayectoria de un robot UR5 [Tesis de Título Profesional, Universidad de Ingeniería y Tecnología]. Repositorio Institucional UTEC. https://hdl.handle.net/20.500.12815/354es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12815/354
dc.description.abstractActualmente, se pueden utilizar robots para llevar a cabo cirugías mínimamente invasivas. Los cirujanos pueden controlar estos robots con dispositivos padres. Sin embargo, existe un problema al utilizar estos robots: la falta de retroalimentación háptica. Para solucionar este problema se suelen optar por dispositivos comerciales, los cuales no están diseñados para usarse en cirugías. Al usar estos dispositivos, se presentan problemas de movimientos no deseados debido a la falta de actuación en todos sus grados de libertad. Asimismo, la imposibilidad de mantenerse en una posición fija complica a los cirujanos debido a que tienen que sostener estos dispositivos durante toda la cirugía. Sabiendo ello, el presente trabajo aborda el diseño e implementación de un prototipo de dispositivo háptico orientado a cirugía. Este prototipo sirve como dispositivo padre que cuenta con 7 grados de libertad y comanda posiciones a un robot hijo UR5. En el diseño, se empleó la configuración articular Z-X-Z basado en la literatura. Luego, se optimizaron los ángulos mínimos y máximos del dispositivo con algoritmos genéticos, obteniendo una mejora del 27 % al abarcar el espacio de un cubo de 35 cm necesario para cirugía. Seguido a ello, se implementó el controlador PD con compensación de gravedad para garantizar que el dispositivo sea capaz de mantener su última posición. El resultado del controlador PD mostro un error de posición del 0.14 %. Por otro lado, se implementó el control PID de orden fraccionario de torque para generar la sensación háptica en el efector final del prototipo. Este controlador obtuvo un error de torque del 0.6 % con un tiempo de establecimiento de 0.1 segundo. Finalmente, se generaron dos trayectorias espaciales (cerrada y abierta) en X-Y-Z con un error de 6.2 mm y 19.2 mm para la simulación e implementación, respectivamente.es_PE
dc.description.abstractNowadays, it is usual to use robots to perform minimally invasive surgery. Surgeons can control these robots with parent devices. However, there is a problem when using these robots: the lack of haptic feedback. To solve this problem, commercial devices are often chosen, which are not designed for surgeries. When use these devices, there are problems of unwanted movements due to the lack of actuation in all its degrees of freedom. Also, the impossibility of staying in a fixed position complicates surgeons because they have to hold these devices during the whole surgery. Considering this, the present work addresses design and implementation of a surgeryoriented haptic device prototype. This prototype serves as a parent device that has 7 degrees of freedom and commands positions to a UR5 child robot. In the design, the Z-X-Z joint configuration based on literature was used. Then, the minimum and maximum angles of the device were optimized, obtaining an improvement of 27 % to cover the space of a 35 cm cube required for surgery. Following this, the PD controller with gravity compensation was implemented to ensure that the device is able to maintain its last position. The result of the PD controller showed an error of 0.14 %. On the another hand, the torque fractional order PID control was implemented to generate the haptic sensation in the end effector of the prototype. This controller obtained an error of 0.6 % with a settling time of 0.1 second. Finally, a closed trajectory with an error of 6.2 mm and open trajectory with an error of 19.2 mm were generated for simulation and implementation, respectively.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad de Ingeniería y Tecnologíaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRepositorio Institucional UTECes_PE
dc.sourceUniversidad de Ingeniería y Tecnología - UTECes_PE
dc.subjectProcedimientos Quirúrgicos Robotizadoses_PE
dc.subjectInterfaces Hápticases_PE
dc.subjectProcedimientos quirúrgicos mínimamente invasivoses_PE
dc.subjectControladores PIDes_PE
dc.subjectDiseño y construcción de robotses_PE
dc.subjectRobóticaes_PE
dc.subjectRobots quirúrgicoses_PE
dc.subjectRobotic surgical procedureses_PE
dc.subjectHaptic interfaceses_PE
dc.subjectMinimally invasive surgical procedureses_PE
dc.subjectPD Controles_PE
dc.subjectRobot design & constructiones_PE
dc.subjectRoboticses_PE
dc.subjectSurgical robotses_PE
dc.titleDiseño e implementación de un prototipo de dispositivo háptico de 7 GDL orientado a cirugía con control fraccionario de torque y compensación de gravedad para el control de trayectoria de un robot UR5es_PE
dc.title.alternativeDesign and implementation of a 7 dof surgery-oriented haptic device prototype with fractional torque control and gravity compensation for trajectory control of a UR5 robotes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.00.00es_PE
dc.publisher.countryPEes_PE
thesis.degree.disciplineIngeniería Mecatrónicaes_PE
thesis.degree.grantorUniversidad de Ingeniería y Tecnología. Ingeniería Mecatrónicaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.nameIngeniero Mecatrónicoes_PE
renati.advisor.dni42141373
renati.advisor.orcidhttps://orcid.org/0000-0002-5077-7526es_PE
renati.author.dni72293837
renati.author.orcidhttps://orcid.org/0000-0001-5873-7994es_PE
renati.discipline713096es_PE
renati.jurorRojas Moreno, Arturo
renati.jurorMichhue Vela, Gabriel Percy
renati.jurorAranda Egúsquiza, Sergio
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess