Advanced search

Show simple item record

dc.contributor.advisorMurray Herrera, Victor Manuel
dc.contributor.authorGonzales Vera, Ricardo Alonso
dc.contributor.authorSeemann, Felicia
dc.contributor.authorLamy, Jérôme
dc.contributor.authorArvidsson, Per M.
dc.contributor.authorHeiberg, Einar
dc.contributor.authorPeters, Dana C.
dc.date.accessioned2021-08-17T21:42:16Z
dc.date.available2021-08-17T21:42:16Z
dc.date.issued2021-06-19
dc.identifier.citationGonzales, R. A., Seemann, F., Lamy, J., Arvidsson, P. M., Heiberg, E., Murray, V. y Peters, D. C. Automated left atrial time-resolved segmentation in MRI long-axis cine images using active contours. BMC Med Imaging 21, 101 (2021). https://doi.org/10.1186/s12880-021-00630-3es_PE
dc.identifier.issn1471-2342es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12815/244
dc.descriptionArtículo sustentado el 22 de Julio 2021 para la obtención del título profesional de Ingeniero Electrónico.es_PE
dc.description.abstractBackground: Segmentation of the left atrium (LA) is required to evaluate atrial size and function, which are important imaging biomarkers for a wide range of cardiovascular conditions, such as atrial fbrillation, stroke, and diastolic dysfunction. LA segmentations are currently being performed manually, which is time-consuming and observer-dependent. Methods: This study presents an automated image processing algorithm for time-resolved LA segmentation in cardiac magnetic resonance imaging (MRI) long-axis cine images of the 2-chamber (2ch) and 4-chamber (4ch) views using active contours. The proposed algorithm combines mitral valve tracking, automated threshold calculation, edge detection on a radially resampled image, edge tracking based on Dijkstra’s algorithm, and post-processing involving smoothing and interpolation. The algorithm was evaluated in 37 patients diagnosed mainly with paroxysmal atrial fibrillation. Segmentation accuracy was assessed using the Dice similarity coefcient (DSC) and Hausdorf distance (HD), with manual segmentations in all time frames as the reference standard. For inter-observer variability analysis, a second observer performed manual segmentations at end-diastole and end-systole on all subjects. Results: The proposed automated method achieved high performance in segmenting the LA in long-axis cine sequences, with a DSC of 0.96 for 2ch and 0.95 for 4ch, and an HD of 5.5 mm for 2ch and 6.4 mm for 4ch. The manual inter-observer variability analysis had an average DSC of 0.95 and an average HD of 4.9 mm. Conclusion: The proposed automated method achieved performance on par with human experts analyzing MRI images for evaluation of atrial size and function.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isoenges_PE
dc.publisherUniversidad de Ingeniería y Tecnologíaes_PE
dc.publisherBioMed Centrales_PE
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRepositorio Institucional UTECes_PE
dc.sourceUniversidad de Ingeniería y Tecnología - UTECes_PE
dc.subjectActive contourses_PE
dc.subjectCardiovascular imaginges_PE
dc.subjectMagnetic resonance imaginges_PE
dc.subjectLeft atriumes_PE
dc.subjectSegmentationes_PE
dc.titleAutomated left atrial time-resolved segmentation in MRI long-axis cine images using active contourses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.02.01es_PE
dc.publisher.countryPEes_PE
thesis.degree.disciplineIngeniería Electrónicaes_PE
thesis.degree.grantorUniversidad de Ingeniería y Tecnología. Ingeniería Electrónicaes_PE
thesis.degree.levelTítulo profesionales_PE
thesis.degree.nameIngeniero Electrónicoes_PE
dc.identifier.doihttps://doi.org/10.1186/s12880-021-00630-3
dc.identifier.journalBMC Medical Imaginges_PE
renati.advisor.dni40703463
renati.advisor.orcidhttps://orcid.org/0000-0002-6000-3380es_PE
renati.author.dni72692721
renati.author.orcidhttps://orcid.org/0000-0002-9384-4602es_PE
renati.discipline712026es_PE
renati.jurorRojas Moreno, Arturo
renati.jurorValdivia Silva, Julio Ernesto
renati.jurorAranda Egúsquiza, Sergio
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/closedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/closedAccess