dc.contributor.advisorCanahuire Cabello, Ruth Vanessa
dc.contributor.authorMonterrey Ikeda, Christian Aarón
dc.date.accessioned2022-03-10T16:40:34Z
dc.date.available2022-03-10T16:40:34Z
dc.date.issued2022
dc.identifier.citationMonterrey Ikeda, C. A. (2022). Diseño de un sistema de drenaje activo para el tratamiento del glaucoma [Tesis de Título Profesional, Universidad de Ingeniería y Tecnología]. Repositorio Institucional UTEC. https://hdl.handle.net/20.500.12815/268es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12815/268
dc.description.abstractEl glaucoma es la segunda causa de ceguera a nivel mundial sólo por detrás de la catarata. Esta afección está relacionada a la elevación en la presión intraocular, originada en la mayoría de casos por la falla del sistema de drenaje del ojo. Dentro de los métodos convencionales para el tratamiento del glaucoma se encuentran el uso de gotas oftálmicas, para la disminución de la presión interna del ojo, y la cirugía laser para la creación de canales artificiales de drenaje. En caso los métodos anteriores no sean efectivos en el paciente, se procede a implantar quirúrgicamente un dispositivo de drenaje en la superficie del globo ocular. Estos dispositivos funcionan bajo un principio de activación pasiva, y en la mayoría de los casos no poseen una buena precisión al momento de realizar el drenaje, ocasionando complicaciones como la hipotonía post-operativa. Es por ello que este trabajo se centra en el diseño de un sistema de drenaje activo, que posea mayor precisión con respecto a los dispositivos actuales y sea capaz de evitar la hipotonía en el tratamiento del glaucoma. El sistema activo debe ser lo suficientemente pequeño para ser implantado dentro del globo, así como también preciso al momento de realizar el drenaje; en ese sentido, se utiliza tecnología basada en Microelectromechanical Systems (MEMS) con la finalidad de cumplir con ambos requisitos. El sistema activo cuenta con un sensor piezorresistivo, colocado sobre la superficie de la córnea, que mide constantemente la presión interna del ojo, y a partir de dichas mediciones se decide, o no, activar una válvula piezoeléctrica que realiza el drenaje, colocada en el espacio intraescleral del globo. La presente tesis muestra los resultados de simulación del sistema activo utilizando el modelo computacional del ojo en el software COMSOL Multiphysics.es_PE
dc.description.abstractGlaucoma is the second leading cause of blindness worldwide only behind cataract. This condition is related to elevated intraocular pressure, caused in most cases by the malfunctioning of the eye drainage system. Among the conventional methods for the treatment of glaucoma are the use of eye drops, to decrease the intraocular pressure, and laser surgery to create artificial drainage channels. If these methods are not effective in the treatment of the patient, a drainage device is surgically implanted on the surface of the eyeball. These devices work under a passive activation principle, and in most cases they do not have good precision performing the drainage, causing complications such as post-operative hypotony. In that sense, this work focuses on the design of an active drainage system, which has greater precision with respect to the current devices and is capable of avoiding hypotony in the treatment of glaucoma. The active system must be small enough to be implanted within the eye, as well as precise at the drainage; Hence, technology based on Microelectromechanical Systems (MEMS) is used in order to satisfy both requirements. The active system has a piezoresistive sensor, placed on the surface of the cornea, which constantly measures the internal pressure of the eye, and from these measurements it is decided, whether or not, to activate a piezoelectric valve that performs the drainage, placed in the intrascleral space of the eye. This work shows the simulation results of the active system using the computational model of the eye in the COMSOL Multiphysics software.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad de Ingeniería y Tecnologíaes_PE
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRepositorio Institucional UTECes_PE
dc.sourceUniversidad de Ingeniería y Tecnología - UTECes_PE
dc.subjectGlaucomaes_PE
dc.subjectPresión Intraoculares_PE
dc.subjectHipotonía oculares_PE
dc.subjectSistemas micro electromecánicoses_PE
dc.subjectIntraocular Pressurees_PE
dc.subjectOcular hypotonyes_PE
dc.subjectMicroelectromechanical systemses_PE
dc.titleDiseño de un sistema de drenaje activo para el tratamiento del glaucomaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.02.01es_PE
dc.publisher.countryPEes_PE
thesis.degree.disciplineIngeniería Electrónicaes_PE
thesis.degree.grantorUniversidad de Ingeniería y Tecnología. Ingeniería Electrónicaes_PE
thesis.degree.levelTítulo profesionales_PE
thesis.degree.nameIngeniero Electrónicoes_PE
renati.advisor.dni42141373
renati.advisor.orcidhttps://orcid.org/ 0000-0002-5077-7526es_PE
renati.author.dni76673976
renati.author.orcidhttps://orcid.org/ 0000-0002-7687-7146es_PE
renati.discipline712026es_PE
renati.jurorRojas Moreno, Arturo
renati.jurorRodríguez Bustinza, Ricardo
renati.jurorAranda Egúsquiza, Sergio
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(es)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/restrictedAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/restrictedAccess